Buy The manometers signaling Dm2005sg, Dv2005sg, Da2005sg, to EKM-1U, EKM-2U, EKV, EKMV
The manometers signaling Dm2005sg, Dv2005sg, Da2005sg, to EKM-1U, EKM-2U, EKV, EKMV

The manometers signaling Dm2005sg, Dv2005sg, Da2005sg, to EKM-1U, EKM-2U, EKV, EKMV

In stock
Price from:
1150 UAH
Wholesale:
  • 1050 UAH/pcs  - from 10 pcs
Shipping:
Ukraine, Kharkov
(View map)

Company rating

88% of positive reviews from 8
Technical characteristics
  • BrandМанотомь
  • Country of manufactureRussia
  • TypeTubular
  • DesignationElectrocontact
  • Measurement rangeот 1 kg
  • Case diameter160 mm
  • Class of accuracy1,5
Description

The manometers, compound pressure gages and vacuum meters showing electrocontact ekm, ekv and ekvm are made with the closing, and also disconnecting contacts of signaling devices working at the lower and upper preset value of pressure.

The manometer electrocontact ekm or the so-called manometer with the electric alarm system regulate the measured environment due to availability of the electrocontact mechanism. Are made in 2 executions: on the basis of an electrocontact prefix, and also using microswitches.

Use to measure the excessive and vacuum gage pressure of different environments and to manage external electrochains from the signaling device of direct action.

Technical datas

Materials of parts:

  • body: steel, aluminum alloy
  • glass: cast
  • tubular spring: copper alloy, zhelezonikiliyevy alloy
  • holder: copper alloy
  • mechanism: bronze, stainless steel
  • Devices maintain impact of vibration in the range of frequencies from 5 to 35 Hz with an amplitude of 0,35 mm (L1 group in accordance with GOST 12997-84)
    Degree of protection against penetration of dust and water in accordance with GOST 14254-96
  • by default degree of protection of IP40 in accordance with GOST 14254-96
  • IP53 - by request degree of protection of IP53 in accordance with GOST 14254-96
    Flange for fastening of the device on the panel
  • by default devices are delivered without flange
  • Ф - by request devices are delivered with a back arrangement of a flange
    Thread of the connecting union
  • by default metric thread of M20*1,5-8g
  • G1/2-B - by request an inch thread
  • R1/2 - by request a taper thread
    Damper for clearing of pulsating pressure
  • by default devices are delivered without damper to 16 kgfs/cm2 inclusive and with a damper over 25 kgfs/cm2 inclusive
  • by request the damper is established in the device with any indication range
    Tension of the external switched chains:
  • 380 V (including 24 - 27 - 36 - 40 - 110 - 220B) - for chains of variable current -
  • 220 V (including 24 - 27 - 36 - 40 - 110B) - for direct current circuits
  • Rupturing capacity of contacts for the signaling device:
  • with the sliding contacts - 10 W of a direct current and 20 V • And variable current -
  • with magnetic contraction of contacts - 30 W of a direct current and 50 V • And alternating current
    Value of the switched current:
  • for the signaling device with the sliding contacts - from 0,02 to 0,5 And -
  • for the signaling device with magnetic contraction of contacts - from 0,01 to 1 And
  • Limit of the allowed key industry of operation of the signaling device:
  • for the signaling device with the sliding contacts of 2,5%
  • for the signaling device with magnetic contraction of contacts of 4%

Limits of indications:

- at Dm2005sg from zero to 1, 1,6, etc. to 1,6 kgfs / sq. cm -

- at Dv2005sg from-1 to zero kgf/quarter of cm -

- at Da2005sg from-1 to 0,6 - 1,5, etc. to 24 kgfs / sq. cm -

? body diameter - 16 cm -

- weight - is no more than 1,6 kg -

- the term of operation is on average equal to 10 years.

Materials of parts:

- the body of devices is manufactured of steel and an aluminum alloy -

- glass: cast -

- the holder from a copper alloy -

- a tubular spring from a copper and zhelezonikiliyevy alloy -

- the mechanism from bronze, stainless steel

Climatic modification (according to state standard specification 15150-69)

U3 - by default the range of working temperature indicators from - 50 to +60 degrees -

T3 - according to the order the range of working temperature indicators from - 50 to +60 degrees.

The measured environment

- steam, liquid, gas, including propane and butane - by default -

- gaseous and liquid oxygen - by request.

The signaling device for connection of external chains possesses four options of execution according to state standard specification 2405-88:

- by default V - the right closing contact (max) and left disconnecting (min) - indexes blue -

- III - 2 disconnecting contacts: the right index (max) - red color - left (min) - blue -

- IV - 2 closing contacts: the right index (max) is blue, and left (min) - red -

- VI - indexes and the left closing contact (min) and right disconnecting (max) - red color.

Shipping method
Contact the seller
The manometers signaling Dm2005sg, Dv2005sg, Da2005sg, to EKM-1U, EKM-2U, EKV, EKMV
The manometers signaling Dm2005sg, Dv2005sg, Da2005sg, to EKM-1U, EKM-2U, EKV, EKMV
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0