Buy Sensor for measuring hydrogen peroxide
Sensor for measuring hydrogen peroxide

Sensor for measuring hydrogen peroxide

Code: ASO0003301
In stock
Price:
48776 UAH
For example: +380(50)123-45-67
Payment:
  • Cash,
  • Non-cash,
  • Visa/Mastercard,
  • Cash on delivery,
  • MoneyGram,
  • Western Union,
  • Credit card,
  • T/T - Telegraphic Transfer,
  • L/C - Letter of Credit,
  • D/P - Documents against Payment,
  • D/A - Documents against acceptance
  • In detail
Shipping:
  • Customer pickup,
  • Courier,
  • Transport company
  • In detail
Ukraine, Rovno
(View map)
+380 
Display phones

Company rating

100% of positive reviews from 3
11
11 years on Allbiz
Technical characteristics
  • BrandETATRON D. S.
Description
SONDA HP sensor for measuring hydrogen peroxide, is supplied with the electrolyte. The construction and operation of amperometric (potentiostatic) sensor gated Etatron SONDA HP - is a closed galvanic cell (similarity batteries), which has a cathode (gold or platinum) and the anode (silver or copper). For automatic temperature compensation readings electrodes integrated fluid temperature sensor. The cell is filled with electrolyte and separated from the medium by a membrane which prevents electrolyte loss and passes only necessary to measure the composition of the measured fluid is also filtered by unnecessary and harmful impurities. All that passes the membrane - is a source of generation of current to the sensor electrodes. The filter membrane composition enters the filling electrolyte sensor, which decomposes at the cathode. The resulting ions are transferred to the anode, where oxidation occurs them - is a current proportional to the concentration of the analyte in the water level and which was necessary to measure. The housing also has a chip that handles current coming from the electrodes and the integrated temperature sensor, converts a voltage (potential) of the controller processing suitable for dosing reagents SONDA HP sensor is compatible with the presence of surface-active compounds (surfactants). Measurement of hydrogen peroxide produced in the range of 2 - 11 pH. Measurement range: 0 - 200 ppm (0 - 200 mg / l). For SONDA HP sensor requires constant flow of 30-40 l / h. Rated allowed back into the bypass system - 1 bar. Maximum allowable back pressure in the bypass system - 5 bar (gauge when mounted on the thrust ring). Maximum flow liquid temperature: 45 ° C. Automatic temperature compensation. The connection cable is not included (sold separately)
Shipping method
Payment method
Contact the seller
Sensor for measuring hydrogen peroxide
Sensor for measuring hydrogen peroxide
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0