Technical characteristics
  • BrandVents
  • Country of manufactureUkraine
Description

LLC ASR-GROUP offers on sale  the BEHTC VUT forced-air and exhaust installations 300 E2V of the EU with utilization of thermal energy for a frigid climate. Their productivity makes up to 300 m3/h in a compact zvuko-and the heatisolated case with the branch pipes directed vertically.

The BEHTC VUT forced-air and exhaust installation 300 E2V of the EU represents completely ready ventilating unit providing a filtration, supply of fresh air to the room and removal polluted, at the same time warmly exhaust air is transmitted to stitched air through a lamellar recuperator. Installations are intended for power effective ventilation of private houses and apartments in the conditions of low temperatures of external air. All models are intended for connection with round air ducts. Installations are applied in rooms of different function.

The BEHTC VUT case 300 E2V of the EU is manufactured of two-layer alyumotsinkovy steel with internal warm and sound insulation from mineral wool 20 mm thick.

For a filtration of stitched and exhaust air in installation there are two built-in filters of pocket type with extent of cleaning of G4. As a separate option the replaceable filter with a class of cleaning F7 is offered.

In installation the highly effective motors of a direct current elktronno-switched (EU) with an external rotor with recurved shovels are used. The EU motors are characterized by high efficiency and optimum control in all range of speeds of rotation. Speeds of rotation are adjusted individually for stitched and exhaust fans at a stage of adjustment of system.

Lamellar recuperator of counterflow type with high efficiency of return of heat (to 95%), made of polystyrene. Under the block of a recuperator the pallet for collecting and removal of condensate is located. Protection of a recuperator against freezing is carried out by means of electric preheating of street air.

The BEHTC VUT forced-air and exhaust installations 300 E2V of the EU are equipped with two electric heaters. The first heater located before a recuperator heats the air arriving from the street to temperature excluding frosting of a recuperator, and, the recovery maintaining maximum efficiency. The second heater located after a recuperator
heats pritochny air to comfortable temperature.

BEHTC VUT 300 E2V EU is also equipped with the control panel which is taken out on a cable 10 m long with graphic
display. All installations are completed with the remote control of management. They are intended for internal installation on the glazed balconies, in utility rooms, on attics at ambient temperature not below -15 °C.

In case of work of installation at negative ambient temperatures the thermal isolation of a drainage branch pipe excluding condensate freezing has to be provided. Installation fastens to a wall by means of anchor bolts or is put on a floor in the situation providing collecting and removal of condensate in a drainage. Access for service and cleaning of filters is from the forward folding panel.

Dear clients, pay, please, attention to that fact that electric connection and installation have to be carried out according to the instruction and an electric circuit specified on a terminal box!

Delivery of the ventilating equipment is carried out to any region of Ukraine. For this purpose you need to choose only the most convenient for you a way of delivery .

On all questions which at you arose concerning acquisition of the VUT forced-air and exhaust installation , please, address our specialists in contact phones .

Do the order!

Characteristics
The main
The producer - VENTS
Country producer Ukraine
Weight 38.0 (kg)
Additional characteristics
Installation supply voltage, In/50 Hz (mines / sredn / max.) 1 ~ 230
The maximum power of fans, W (at a speed of 1/2/3) 30/107/212
Current of fans, And (at a speed of 1/2/3) 0,3/0,8/1,4
Power of the electric heater, kW 2 pieces x 2
Current of the electric heater, And 2 pieces x 8,7
Total power of installation, kW 4,212
Most consumed installation current, And 18,8
The maximum consumption of air, m3/hour (at a speed of 1/2/3) 80 / 160 / 300
Level of sound pressure on rasst. 3 m, dB(A) (at a speed of 1/2/3) 10/19/32
Temperature of the moved air, °C from - 39 to +60
Case material alyumotsink
Isolation 20 mm min. cotton wool
Filter: extract/inflow pocket G4 (code of the order of the SFK 300 E2B replaceable filter of the EU G4 / SFK 300 E2B of the EU F7)
Diameter of the connected air ducts, mm 150
Efficiency of recovery to 95%
Recuperator type counterflow
Recuperator material polystyrene
Shipping method
Payment method
Contact the seller
Forced-air and exhaust installation of Vents Vut 300 E2V EU
Forced-air and exhaust installation of Vents Vut 300 E2V EU
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0