(View map)
Dividers membrane PM 5320
Dividers membrane PM 5320 from stainless steel are intended for protection of an internal cavity of sensitive elements of measuring devices against hit Wednesdays in it. aggressive, hot, crystallizing, bearing the weighed firm particles that can prizvest to failure of the devices controlled working process.
The PM5320 connection with the measuring device is carried out with the help the connecting sleeve delivered upon the demand of the customer.
SPECIFICATIONS
The top limit of measurement of the PM 5320 device completed by a divider to 2,5 (25) MPas (kgf/cm2):
Volume of an elastic sensitive element of the measuring device, cm3: for fashions. 5320
40
The additional error of measurement brought by the dividers connected to measuring devices should not exceed +1% of the normalizing device.
Temperature of the measured environment on an entrance of a divider of PM5320 has to correspond to temperature range from - 30C to + 60C.
Note. Dividers are always applied with a connecting sleeve if temperature of the measured environment on an entrance of a divider is higher than temperature established for operation of the measuring device.
Material of details of the dividers contacting to the measured environment:
membrane: alloy 36NHTYu
flange, case: Art. 12X18H10T
Length of a connecting sleeve, m: 2,5
On special to the order length of a sleeve can be increased to 10 m.
Mass of dividers, kg, no more:
for fashions. 5320 2,0