Buy Copper gas double-circuit wall Protherm Lynx 28
Copper gas double-circuit wall Protherm Lynx 28

Copper gas double-circuit wall Protherm Lynx 28

In stock
Price:
13850 UAH
Shipping:
Ukraine, Lutsk
(View map)
Technical characteristics
  • BrandProtherm
  • Country of manufactureCzech Republic
  • Weight30,5-33 kg
  • Installation methodWall mounted
  • Coefficient of performance (COP)93 %
Description
Copper gas double-circuit wall Protherm Lynx 28

Copper gas double-circuit wall Protherm "Lynx" 28 with function of preparation of hot water. The built-in block of electronic control provides electronic ignition of a torch and control of burning, and also continuous modulation of gas. Average efficiency for a heating season of 93%. The information display on the control panel of a gas copper. Compulsory withdrawal of products of combustion.

Lynx 24 Lynx of BA 24 Lynx 28
General characteristics
Article 0010010833 0010010835 0010010835
Category of gas II2H3P II2H3P II2H3P
Performance C12, C32, C42, C52 B11BS C12, C32, C42, C52
Ignition electronic electronic electronic
Fuel natural gas (propane) natural gas (propane) natural gas (propane)
Max. / Min. thermal power (kW) 23,5 / 9,2 25,6 / 11,5 11,3 / 27
Max. / Min. thermal useful power (kW) 10,5 / 25,3 27 / 11,3 13 / 29,1
EFFICIENCY (%) 93 91,1 92.9
Technical characteristics
Heating
Max. / Min. working pressure (bar) 3 / 0,8 3 / 0,8 3 / 0,8
Recommended the working pressure (bar) 1,5 1,5 1,5
Range of regulation of temperatures (°C) max. 85 max. 85 max. 85
Broad tank (l) 7 7 7
Maximum pressure of a broad tank (bars) 3 3 3
Hot water
Max. / Min. pressure (bar) 8 / 0,25 8 / 0,25 8 / 0,25
Minimalny Canal of GVS (l/min.) 2,5 2,5 2,5
GVS expense (at T 30 °C) (l/min.) 10,7 10,5 12,7
Range of temperature (°C) max. 64 max. 64 max. 64
Removal of exhaust gases
Way of removal of exhaust gases turbo flue turbo
Diameter of a flue (mm) 60/100, 80/80 130 60/100, 80/80
Temperature of combustion gases (°C) 106,7 / 94,3 102/71 116,5 / 94,3
Weight exit of exhaust gases (/c) 13,89 / 14,04 15,56 / 15,8 13,4
Noise level (dB) <50 <51 <52
Gas parameters
Natural gas
Max. / Min. consumption of gas (m3/hour) 2,677 / 1,111 3,079 / 1,376
Pressure on an entrance (Mbar) 20 20
Diameter of a membrane (mm) - -
The maximum pressure on nozzles (Mbar) 13 14
The minimum pressure on nozzles (Mbar) 2,4 2,6
Diameter of a nozzle (mm) 1,3 1,25
Propane
Max. / Min. consumption of gas (kg/h) 1,965 / 0,816 2,26 / 1,009
Pressure on an entrance (Mbar) 37 37
Diameter of a membrane (mm) - -
The maximum pressure on nozzles (Mbar) 35,8 34,8
The minimum pressure on nozzles (Mbar) 6,5 7,6
Diameter of a nozzle (mm) 0,79 0,79
Electric parameters
Tension/Frequency (In/Hz) 230/50 230/50
Power (W) 98 98
Electric protection IPX4D IPX4D
Current (A) - -
Overall dimensions and weight
The sizes - height/width/depth (mm) 700/410/280 720/405/280 700/444/280
Weight without water (kg) 30,5 30.5 33
Shipping method
Contact the seller
Copper gas double-circuit wall Protherm Lynx 28
Copper gas double-circuit wall Protherm Lynx 28
for
by the goods
Your message must contain at least 20 symbols. The message must not be more than 2000 symbols.
Obligatory field is not filled
The field is wrongly filled
The field is wrongly filled
Compare0
ClearSelected items: 0