Buy Controller of weight RMWC
Controller of weight RMWC

Controller of weight RMWC

In stock
Reconfirm the price with seller
Payment:
Shipping:
Seller
Ukraine, Kharkov
(View map)
+380 
Display phones
7
7 years on Allbiz
Technical characteristics
  • Control methodAutomatic
  • Form of substanceSolid bulk material
Description

Controller of weight RMWC

The RMWC controller - is intended for prescription dosing stations with one or two tensometric systems and control of the external batcher mixer of water. Forms doses from one to eight automatically weighed components and water and keeps account. Memory to 90 recipes with information output on LCD - the display. Has 2 RS 485 and RS 485/422 ports for communication with external PC/PLC. -

Description

The RMWC controller - is intended for prescription weight discrete weighing of loose and liquid products serving up to two independent tensometric systems on which bunkers of batchers are installed and to operate the discrete volumetric batcher of DOX water - or the DOMIX water batcher mixer which can participate in process of prescription dispensing, carrying out reception / data transmission of the account on each product and settings from (v) PC/PLC.

The RMWC controller (the weight computer, the weight terminal) - forms a prescription dose from 1 … 8 components and doses of water of the set temperature.

Dispensing is carried out by the principle of a consecutive set of weight of 1-8 components in one bunker or at the same time in 2 bunkers (totally no more than 8 components) with the subsequent consecutive unloading of a total prescription dose.

If in installation the automatic batcher mixer of DOMIX water is used, the controller counts necessary water temperature - (based on the required temperature of a prescription dose, the actual temperature of the dosed component and ambient temperature) and sends the calculated value of water temperature and a preset value of quantity to the water batcher mixer with team of the beginning of process.

If the compounding provides manual addition of components, the operator has to follow only instructions on LCD - the display and to load manually components into capacity (after weighing manually on external scales).

High precision of dispensing is provided with ample program opportunities - the RMWC controller on creation necessary - a control algorithm of the equipment of the dosing complex.

The RMWC controller - carries out exact accumulative - the account on each dosed product and remembers up to 90 recipes for the subsequent automatic repetition with the indication of manual operations of dispensing of components.

Structurally weight RMWC controller is executed in the form of the tight module, with the front panel from aluminum 3 mm thick in which are established electronics payments closed by a protective box from galvanized steel on which all connections for entrances, exits and giving of food are provided.

On the forward panel the full user interface consisting of buttons of management, LED indicators of a condition of work, the LCD display with area of the viewing of 120x92 mm participating in programming and display of process of working off of the required prescription dose, and, united in one window, 4 digital LED displays for information output from 2 tensometric and 4 temperature sensors is located.

The RMWC controller - has 2 ports of communication: RS 485 for control of all possible coordinated devices (for example, the DOMIX water batcher mixer, etc.) and RS 485/422 for connection to external PC/PLC by means of MODBus ASCII or the RTU protocol that allows to collect necessary statistical information of the account on each dosed product on remote PC/PLC and to operate the RMWC controller.

The quantity of the served tensometric systems

To the 2nd (at most - to 4 tensometric sensors everyone)

The number of the remembered recipes

To 90

Quantity of automatically dosed weight components

To 8 (totally on 2 tensometric systems in any ratio)

Digital entrances (dry contacts)

  •  - - - - - - - - Remote start-up of START
  •  - - - - - - - - Remote stop of STOP
  •  - - - - - - - - Remote opening of the gate of the bunker 1
  •  - - - - - - - - Remote opening of the gate of the bunker 2
  •  - - - - - - - - Remote unloading
  •  - - - - - - - - Remote launch of the batcher of water
  •  - - - - - - - - Microswitch of closing of the gate of the bunker 1
  •  - - - - - - - - Microswitch of closing of the gate of the bunker 2
  •  - - - - - - - - RESERVE
  •  - - - - - - - - 2 entrances for STM counters of an expense of liters of water (possible use)

Analog entrances

  •  - - - - - - - - Sensor of surrounding temperature Pt 100 Class A
  •  - - - - - - - - The sensor of temperature of flour in the bunker 1 Pt 100 Class A
  •  - - - - - - - - The sensor of temperature of liquid components in the bunker 2 Pt 100 Class A
  •  - - - - - - - - Sensor of temperature of the Pt 100 Class A test
  •  - - - - - - - - 4-wire connection to a series from at most 4 strain gages of the weight bunker 1
  •  - - - - - - - - 4-wire connection to a series from at most 4 strain gages of the weight bunker 2

Each entrance has 24-bit ATsP (7730). Two channels are independent and can work at the same time.

Entrances connect through M/F quick-detachable terminal blocks by means of the fixing screws. Entrances of strain gages have pomekhozashchishchenny screened round sockets.

Exits

Sound signal (on the computer panel).

19 relays with contacts on explosive power 12A (1 terminal on each and 1 general for everyone 6):

  •  - - - - - - - - 8 relays for transport systems from 8 bunkers (divided between 2 bunkers)
  •  - - - - - - - - Exact dispensing of the bunker 1
  •  - - - - - - - - Exact dispensing of the bunker 2
  •  - - - - - - - - The unloading gate from the bunker 1 (2 independent exits)
  •  - - - - - - - - The unloading gate from the bunker 2 (2 independent exits)
  •  - - - - - - - - The remote light signal the BUNKER 1 is READY
  •  - - - - - - - - The remote light signal the BUNKER 2 is READY
  •  - - - - - - - - 2 for water electrovalves (now are not used)
  •  - - - - - - - - Accident
  •  - - - - - - - - 2 Reserves

Exits connect through M/F quick-detachable terminal blocks by means of the fixing screws.

Communication ports

  •  - - - - - - - - RS 485 for control of all possible coordinated devices (for example, the water batcher mixer, etc.) by means of MODBus ASCII or the RTU protocol.
  •  - - - - - - - - RS 485/422 for connection to external PC/PLC by means of MODBus ASCII or the RTU protocol.

Control panel

  •  - - - - - - - - The graphic LCD display, 320x240 pixels, with white illumination. Area of viewing of 120x92 mm.
  •  - - - - - - - - 1 display with four 7-segment red categories, 13 mm high, for indications of weight of the bunker 1.
  •  - - - - - - - - 1 display with three 7-segment red categories, 13 mm high, for indications of ambient temperature, temperature in the bunker 1 and test temperatures.
  •  - - - - - - - - 1 display with four 7-segment red categories, 13 mm high, for indications of weight of the bunker 2.
  •  - - - - - - - - 1 display with three 7-segment red categories, 13 mm high, for indications of temperature - in the bunker 2.
  •  - - - - - - - - LED indicators: START-UP - yellow, WATER DISPENSING - yellow, the BUNKER 1 is READY - green, the BUNKER 2 is READY - green, FLOUR 1, MUKA 2, - ENVIRONMENT, and DOUGH – red, in the screen.
  •  - - - - - - - - The membrane keyboard from polyester - with touch management, with 19 - buttons:

- - - - - - - - 5 action buttons under the display which functions vary and are described on the display.

- - - - - - - - The FEET button for - dispensing process interruptions at any time.

- - - - - - - - 10 buttons for figures (with alphabetic symbols, as on the keyboard of mobile phones).

- - - - - - - - Decimal point.

- - - - - - - - Cancellation "With".

- - - - - - - - The button of switching of the temperature display "PRODUCT 1/DOSE / ENVIRONMENT", for change of a type of the temperature indications which are read out from the temperature display of the BUNKER 1.

Installation

Panel board

Class of protection of the case

IP44

Class of protection of the external panel

IP65

Protocol of data transmission

ModBus RTU/ASCII Serial

Tension of a power line

~ 220 V (1NPE)

Frequency of a power line

50 Hz

The consumed current

No more than 0,5A

Power consumption

32 W

Range of admissible temperatures at operation

+15 °C? +40 °C

Range of admissible temperatures at storage

- 10 °C? +50 °C

Admissible humidity at operation

Depends on installation, at IP65 to 97% without condensation

Admissible vibrations

0.03 g2/Hz in the range of 10? 75 Hz

Overall dimensions

 385 x 232 x-116 mm

Weight

6,0 kg

Contact the seller
Controller of weight RMWC
Controller of weight RMWC
Shipping method
Payment method
Compare0