Description
CMC10 methane signaling device
The signaling device of CMC10 methane is intended for continuous individual automatic control of a volume fraction of methane in the atmosphere of excavations in the mines dangerous on gas and dust of any category, delivery of the signal light when exceeding of two set thresholds and individual illumination of a workplace.

Description:

  • The signaling device of methane has two thresholds of operation that allows to trace dynamics of change of maintenance of concentration of methane in the atmosphere;
  • In a signaling device of methane lithium - the polymeric rechargeable battery 8,4 A / h is used;
  • The main source of light — a superbright LED;
  • The stabilized luminous flux during all cycle of work
  • Emission spectrum — white (a warm or cold shade, upon the demand of the customer);
  • The built-in controller protects the rechargeable battery from redischarge and a recharge;
  • All operations on calibration, change of installations, control of internal parameters, are carried out in the automatic mode through charging contact of a headlight by means of the module of technological control of MTK.
  • Detector - a thermocatalytic sensor.
  • The signaling device is loaded on all types of charging stations;
  • Modules of autoorganic accounting, positioning, the notification of the Talnakh complexes, SUBR, SAT can be installed.

Technical characteristics:

Name of parameters Value of parameters
Execution on explosion protection and an iskrozashchita RHO of News agency C
Luminous flux of the main source of light at a working light, not less, than A Lm 40
Luminous flux of a reserve light source, not less, than A Lm 15
Illumination from the main source of light, not less, than A Lx 2600
Duration of continuous time of a luminescence, not less, than an hour 10
Control band of thresholds of operation, as a percentage a volume fraction of CH4 - the first threshold of operation of a signaling device - the second threshold of operation of a signaling device 1-2% are automatically 0,5% higher than the first
Blink rate of a lamp of a signaling device, Hz - the first threshold of operation - the second threshold of operation 1±0,2% of 10±2,0%
Actuation time of a signaling device, with, no more 8
Limit of the allowed intrinsic absolute error of operation of a signaling device, as a percentage a volume fraction of CH4 ±0,2
Overall dimensions, mm - cases - headlights 138´108´49 88´83´99
Weight, kg 0,8

The signaling device of methane has: the small weight and dimensions, two thresholds of operation, the thermocatalytic sensor possessing long term of service, high capacity of the rechargeable battery in comparison with analogs.