The block of control of a flame BKP-2R is intended for continuous automatic control of a flame of gorelochny devices in furnace chambers of stationary coppers and industrial furnaces and implementation of independent or consecutive ignition of two gorelochny devices in the automatic mode.
The block is also full analog of the F34.2 device. It is possible to use the block of control of a flame together with the block of protection of a copper of BZK. As sensors it is recommended to use the PNP converters (analog of the FDCh photosensor) for liquid and gaseous fuel or control electrodes of KE for gaseous fuel
MAIN CHARACTERISTICS:
1. The block carries out the following functions:
― transformation of signals from flame sensors to a discrete output signal;
― independent ignition on two channels;
― consecutive ignition of the first and second channels;
― formation of excerpts of time for short circuit of contacts of the output relays intended for management of ignition of a zapalnik and a torch;
― formation of impulses for control of coils of ignition of B115 or similar;
― delivery of tension for control of transformers of ignition of OS 33 or similar;
― power supply of sensors of a flame;
The block can work with the following types of converters;
a) the detecting sensors (control electrodes like KE);
b) PNP converters, frequency FDCh sensors;
c) other types of converters forming an output signal of constant tension in the range from minus 10 to minus 1,5 Century.
2. Quantity of the input channels, unit 2
3. Operation threshold range ― from minus (10+0/-3) to minus (1,5+0,4/-0,2) Century.
4. A return zone on each channel, B 0,5 +/-0,2
5. Block reaction time on each channel, with, no more than 2
6. Output signals:
― change of a condition of contacts of the relay of control of a flame (in the presence of a flame ― contacts are closed);
― change of a condition of contacts of the relay of managing directors of ignition;
― the range of change of endurance of time of T1 and T2 for management of ignition on the first and second channels from (0 +2) to (10 +/-3) with;
― the range of change of total endurance of time for management of ignition on the second channel at inclusion of additional endurance T2d from (0 +2) to (20 +/-6) with;
― endurance of time of collaboration Tsr (100 +/-56) pages.
7. The block gives the following tension for power supply of converters of existence of a flame:
― tension of a direct current (+/-27 +/-3) In ― for power supply of frequency FDCh sensors, PNP converters;
― tension of alternating current (160 +/-20) In, (50 +/-1) Hz ― for power supply of the detecting sensors.
8. Overall dimensions of the block, mm, no more than 120 x 240 x 285
9. Mass of the block, kg, no more than 3,5